Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Command Details: Set_IO_Config_String

Category

Extended

Details

Command Code:

11h

Valid for:

Object

Description

This command is sent from the host application when there is a need to change the default configuration of the safety inputs and outputs. This string is used by networks where there are no other means (e.g. PLC or some other tool) to provide the configuration to the safety module. Consult the specification of the safety module for more information. The byte string passed is generated by HMS and need to be passed unmodified using this command.

Information about this string is located in the specification of the safety module to which the string shall be sent.

  • Command Details

    Field

    Contents

    CmdExt[0]

    (not used)

    CmdExt[1]

    Data[0... n]

    Data (byte string) The data consists of an IO configuration string, where the data format depends on the safety network.

  • Response Details

    (no data)