Anybus® CompactCom 40 - PROFINET IRT IIoT Secure

I&M Data Structures

The I&M records uses the following data structures.

Record

Content

Size

Description

I&M0

Manufacturer Id

2 bytes

PROFINET IO Object (F6h), attribute #2 (Vendor ID/I&M Vendor ID)

Order Id

20 bytes

PROFINET IO Object (F6h), attribute #8 (I&M Order ID)

Serial number

16 bytes

The content will be assigned in the following priority order:

  1. PROFINET IO Object (F6h), attribute #9 (I&M Serial number)

  2. Application Object (FFh), attribute #3 (Serial number)

  3. Default value, assigned during manufacturing

Hardware revision

2 bytes

The content will be assigned in the following priority order:

  1. PROFINET IO Object (F6h), attribute #10 (I&M Hardware revision)

  2. Application Object (FFh), attribute #11 (Hardware version)

  3. Default value, assigned during manufacturing

Software revision

4 bytes

The content will be assigned in the following priority order:

  1. PROFINET IO Object (F6h), attribute #11 (I&M Software revision)

  2. Application Object (FFh), attribute #10 (Firmware version)

  3. Default value, assigned during manufacturing

Revision counter

2 bytes

PROFINET IO Object (F6h), attribute #12 (I&M Revision counter)

Profile Id

2 bytes

PROFINET IO Object (F6h), attribute #13 (I&M Profile ID)

Profile specific type

2 bytes

PROFINET IO Object (F6h), attribute #14 (I&M Profile specific type)

IM version

2 bytes

0101h (Internal, constant value)

IM supported

2 bytes

For submodules belonging to a non–zero API,the returned value is zero. For submodules belonging to API 0, the returned value is 000Eh (IM0-3 supported)

I&M1

Tag Function

32 bytes

Default: All bytes set to blanks

Tag Location

22 bytes

Default: All bytes set to blanks

I&M2

Installation date

16 bytes

Default: All bytes set to blanks

I&M3

Descriptor

54 bytes

Default: All bytes set to blanks

I&M5

IM_Annotation

64 bytes

PROFINET IO object; attribute #26 (IM Annotation). If the application doesn’t support the attribute: Anybus CompactCom 40 PROFINET IRT IIoT

IM_OrderID

64 bytes

PROFINET IO object; attribute #25 (IM Module Order ID).

If the application doesn’t support the attribute: Anybus CompactCom 40 PROFINET IRT IIoT

VendorIDHigh

1 byte

01h

VendorIDLow

1 byte

0Ch

Serial number

16 bytes

Serial number of the Anybus CompactCom

Hardware revision

2 bytes

Hardware version of the Anybus CompactCom

Software revision

4 bytes

Product version of the Anybus CompactCom

See also..