Anybus® CompactCom 40 - PROFINET IRT IIoT Secure

Details: Error Code 1

The error codes below shall be used when providing error responses to the following commands:

  • Get_Record

  • Set_Record

  • Get_IM_Record

  • Set_IM_Record

High nibble (bits 4... 7)

Low nibble (bits 0... 3)

ErrorClass

Meaning

ErrorCode

Meaning

0... 9

Reserved

(reserved)

(reserved)

10

Application

0

Read error

1

Write error

2

Module error

3... 6

(reserved)

7

Busy

8

Version conflict

9

Feature not supported

10... 15

User specific

11

Access

0

Invalid index

1

Write length error

2

Invalid slot/subslot

3

Type conflict

4

Invalid area

5

State conflict

6

Access denied

7

Invalid range

8

Invalid parameter

9

Invalid type

10

Backup

11... 15

User specific

12

Resource

0

Read constrain conflict

1

Write constrain conflict

2

Resource busy

3

Resource unavailable

4... 7

(reserved)

8... 15

User specific

13... 15

User specific

(user specific)

User specific

See also...