Anybus® CompactCom 40 - PROFINET IRT IIoT Secure

Command Details: Prm_Begin_Ind

Category

Extended

Details

Command Code:

1Fh

Valid for:

Object Instance

Description

This command is optional. The module issues this command to indicate to the host application that a parameterization phase, outside of the connection establishment, is initiated. During the parameterization phase the host application may receive Set_Record commands targeting the submodules addressed by the Prm_Begin_Ind command.

  • Command Details

    Msg field

    Contents

    Comments

    CmdExt[0]

    AR handle (low byte)

    Handle for the Application Relationship (AR)

    CmdExt[1]

    AR handle (high byte)

    Data[0]

    API (low word, low byte)

    Application Process Instance

    Only valid if Sub-slot > 0

    Data[1]

    API (low word, high byte)

    Data[2]

    API (high word, low byte)

    Data[3]

    API (high word, high byte)

    Data[4]

    Slot (low byte)

    Slot number affected by the command

    Only valid if Sub-slot > 0

    Data[5]

    Slot (high byte)

    Data[6]

    Sub-slot (low byte)

    Sub-slot number affected by the command

    0 — Command applies to all modules in the configuration

    >0 — Command applies to the specified slot/sub-slot

    Data[7]

    Sub-slot (high byte)

  • Response Details

    (no data)