Anybus® CompactCom 40 - PROFINET IRT IIoT Secure

Command Details: Cfg_Mismatch_Ind

Category

Extended

Details

Command Code:

15h

Valid for:

Object Instance

Description

The module issues this command to inform the host application that the configuration in the IO Controller (i.e. the Expected Identification) does not match the configuration defined by the host application (i.e. the Real Identification).

It is optional to implement support for this command.

  • Command Details

    Field

    Contents

    Comments

    CmdExt[0]

    AR handle (low byte)

    Handle for the Application Relationship (AR)

    CmdExt[1]

    AR handle (high byte)

    MsgData[0]

    API (low word, low byte)

    Application Process Instance (API)

    MsgData[1]

    API (low word, high byte)

    MsgData[2]

    API (high word, low byte)

    MsgData[3]

    API (high word, high byte)

    MsgData[4]

    Slot (low byte)

    Slot number of mismatch

    MsgData[5]

    Slot (high byte)

    MsgData[6]

    Subslot (low byte)

    Subslot number of mismatch

    MsgData[7]

    Subslot (high byte)

    MsgData[8]

    Expected Module Identifier (low word, low byte)

    Module identifier (as stated in the GSD file) derived from the IO Controller configuration

    MsgData[9]

    Expected Module Identifier (low word, high byte)

    MsgData[10]

    Expected Module Identifier (high word, low byte)

    MsgData[11]

    Expected Module Identifier (high word, high byte)

    MsgData[12]

    Expected Submodule Identifier (low word, low byte)

    Submodule identifier (as stated in the GSD file) derived from the IO Controller configuration

    MsgData[13]

    Expected Submodule Identifier (low word, high byte)

    MsgData[14]

    Expected Submodule Identifier (high word, low byte)

    MsgData[15]

    Expected Submodule Identifier (high word, high byte)

  • Response Details

    (no data)