Anybus® CompactCom 40 - PROFINET IRT IIoT Secure

Instance Attributes (Instance #1)

Extended

#

Name

Access

Type

Value

1

OnLineTrans

Get

UINT32

Diagnostic counters; keeps track of the number of on-line transitions

2

OffLineTrans

Get

UINT32

Diagnostic counters; keeps track of the number of off-line transitions

3

(reserved)

4

Last AbortInd ReasonCode

Get

UINT16

Reason code for most recent Abort indication

See command details for command AR_Abort

5

AddedApis

Get

UINT16

Returns the number of APIs added (including API 0)

6

ApiList

Get

Array of UINT32

First element will always be zero and the second element will contain an additional API. Length of the array is determined by parameter "AddedApis".

7

EstablishedArs

Get

UINT16

The number of Application Relationships currently established

8

ArList

Get

Array of UINT16

Array of Application Relationship handles. Length of array is determined by parameter "EstablishedArs".

9

-

-

-

-

10

Port 1 MAC Address

Get

Array of UINT8

6 Byte PROFINET Port 1 MAC address

See also...  - Ethernet Host Object (F9h)

11

Port 2 MAC Address

Get

Array of UINT8

6 Byte PROFINET Port 2 MAC address