Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Instance Attributes (Instance #8 Ethernet Communication Settings 2)

Changes have immediate effect.

#

Name

Access

Data Type

Description

1

Name

Get

Array of CHAR

Comm 2

(Multilingual, see page Multilingual Strings)

2

Data type

Get

UINT8

08h (= ENUM)

3

Number of elements

Get

UINT8

01h (one element)

4

Descriptor

Get

UINT8

07h (read/write/shared access)

5

Value

Get/Set

ENUM

Value:

String:

Meaning: (Multilingual, see page Multilingual Strings)

00h

Auto

Auto negotiation (default)

01h

10 HDX

10Mbit, half duplex

02h

10 FX

10Mbit, full duplex

03h

100HDX

100Mbit, half duplex

04h

100FX

100Mbit, full duplex

6

Configured Value

Get

ENUM

Holds the configured value, which will be written to attribute #5 after the module has been reset.

Value:

String:

Meaning: (Multilingual, see page Multilingual Strings)

00h

Auto

Auto negotiation

01h

10 HDX

10Mbit, half duplex

02h

10 FX

10Mbit, full duplex

03h

100HDX

100Mbit, half duplex

04h

100FX

100Mbit, full duplex