Instance Attributes (Instance #6, DHCP Enable)
Value is used after module reset.
# | Name | Access | Data Type | Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Name | Get | Array of CHAR | “DHCP” (Multilingual, see page Multilingual Strings) | |||||||||
2 | Data type | Get | UINT8 | 08h (= ENUM) | |||||||||
3 | Number of elements | Get | UINT8 | 01h (one element) | |||||||||
4 | Descriptor | Get | UINT8 | 07h (read/write/shared access) | |||||||||
5 | Value | Get/Set | ENUM | If read, the actual value will be received. If written, the written value is reflected in attribute #6 until a reset. (Multilingual, see page Multilingual Strings)
| |||||||||
6 | Configured Value | Get | ENUM | Holds the configured value, which will be written to attribute #5 after the module has been reset.
|