Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Instance Attributes (Instance #41, OPC UA Discovery Server)

This instance holds the URL of the OPC UA Discovery server used by the Anybus CompactCom.

#

Name

Access

Data Type

Description

1

Name

Get

Array of CHAR

OPC DS URL

(Multilingual, see page Multilingual Strings)

2

Data type

Get

UINT8

07h (= CHAR)

3

Number of elements

Get

UINT8

80 (Max Discovery server URL length is 80 characters.)

4

Descriptor

Get

UINT8

bit 0: 1 = Read access

bit 1: 1 = Write access

bit 2: 1 = Shared access

5

Value

Get/Set

CHAR[80]

Actual OPC UA Discovery Server

Format: opc.tcp://<hostname/ip-address>[:<port>]. The port is optional to have in the URL, if left out the default value is used: 4840. Value set to this attribute will be used on the next connection attempt towards the discovery server.

If read, the actual value will be received. If written, the written value is reflected in attribute #6 until a restart.

6

Configured value

Get

CHAR[80]

The configured value that will be used after restart