Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Instance Attributes (Instance #3, IP Address)

Value is used after module reset.

#

Name

Access

Data Type

Description

1

Name

Get

Array of CHAR

IP address (Multilingual, see page Multilingual Strings)

2

Data type

Get

UINT8

04h (= UINT8)

3

Number of elements

Get

UINT8

04h (four elements)

4

Descriptor

Get

UINT8

07h (read/write/shared access)

5

Value

Get/Set

Array of UINT8

If read, the actual value will be received. If written, the written value is reflected in attribute #6 until a reset.

Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)

6

Configured Value

Get

Array of UINT8

Holds the configured value, which will be written to attribute #5 after the module has been reset.

Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)