Anybus® CompactCom 40 - PROFINET IRT IIoT Secure

Port Activity

AIDA LED State

Description

Off

No Activity

Orange, flashing

Activity

There is no LED on the front of the Anybus CompactCom 40 PROFINET IRT IIoT Secure showing this indication, but the signal is available in the host application connector according to this table:

AIDA indication

Signal Name, Host Application Connector

Activity on port 1

nLED3B

Activity on port 2

nLED4B

The Port Activity signals are always available in the host application connector in all operating modes except 16 bit parallel. For more information consult the Anybus CompactCom M40 Hardware Design Guide (module) or the Anybus CompactCom B40-1 Design Guide (brick).