Instance Attributes (Instance #1)
#  | Name  | Access  | Data Type  | Default Value  | Comment  | 
|---|---|---|---|---|---|
1  | Safety enabled  | Get  | BOOL  | -  | When TRUE, enables communication with the Safety Module. Note: If functional safety is not supported, this attribute must be set to FALSE.  | 
2  | Baud Rate  | Get  | UINT32  | 1020 kbit/s  | This attribute sets the baud rate of the communication in bits/s between the Anybus CompactCom and the Safety Module. Valid values: 
 Any other value set to this attribute, will cause the module to enter the EXCEPTION state. The attribute is optional. If not implemented, the default value will be used. Note: The host application shall never implement this attribute when using the IXXAT Safe T100.  | 
3  | (reserved)  | ||||
4  | Cycle Time  | Get  | UINT8  | -  | Communication cycle time between the Anybus and the Safety module in milliseconds. Note: The host application shall never implement this attribute when using the IXXAT Safe T100. Valid values: 
 If another value is set in this attribute the Anybus will enter Exception state. Optional attribute; If not implemented the minimum cycle time for the chosen baud rate will be used: 
 The Anybus CompactCom validates the cycle time according to the minimum values above. If e.g. baud rate is 625 kbit/s and the cycle time is set to 2 ms the Anybus CompactCom will enter the EXCEPTION state.  | 
5  | FW upgrade in progress  | Set  | BOOL  | False  | Indicates if the Anybus CompactCom is upgrading the connected Safety module firmware. This means that the Anybus CompactCom will stay in the NW_INIT state longer than normal.  |