Network Identity
By default, the module identifies itself as a generic Anybus implementation as follows:
Device ID | 0010h (Anybus CompactCom 40 PROFINET) |
Vendor ID | 010Ch (HMS Industrial Networks) |
Station Type | The Station Type will be assigned a value according to this priority: If the PROFINET IO Object (F6h) is implemented, the value equals that of attribute #3 in instance #1. If the PROFINET IO Object is not implemented, the value of attribute #9 (Product name) in the Application Object (FFh), instance #1, will be used (if implemented). If none of these attributes are implemented, the value equals Anybus CompactCom default value (“CompactCom 40 PIR”). |
It is recommended to customize the identity information so that the Anybus module appears as a vendor specific implementation rather than a generic Anybus product.
See also...
Application Object (FFh) in Anybus CompactCom Software Design Guide