Anybus® CompactCom 40 - PROFINET IRT IIoT Secure

Object Specific Error Codes

Code

Meaning

01h

The ADI has not been mapped with command Map_ADI_Write_Area

02h

The ADI has not been mapped with command Map_ADI_Read_Area

03h

Element does not exist for the ADI

04h

This ADI/element is already mapped

05h

API 0 must be added first

06h

API does not exist

07h

Trying to add an API already present

08h

There is no room for any more APIs

09h

Module in slot 0 cannot have any IO data

0Ah

Prior to plugging the requested module/submodule, slot 0 must be populated with a module and a submodule (in subslot 1)

0Bh

Slot occupied

0Ch

subslot occupied

0Dh

No module inserted in the specified slot

0Eh

No submodule inserted in the specified subslot

0Fh

Slot number specified is out-of-range

10h

subslot number specified is out-of-range

11h

The AR handle provided is not valid

12h

There is no application ready pending

13h

Unknown error (PROFINET IO stack denied the request)

14h

Max number of submodules have already been plugged

15h

Safety module has not been plugged

16h

ADI data type constraint

17h

Safety Module already plugged