Anybus® CompactCom 40 - PROFINET IRT IIoT Secure

Instance Attributes (Instance #6, DHCP Enable)

Value is used after module reset.

#

Name

Access

Data Type

Description

1

Name

Get

Array of CHAR

DHCP

(Multilingual, see page Multilingual Strings)

2

Data type

Get

UINT8

08h (= ENUM)

3

Number of elements

Get

UINT8

01h (one element)

4

Descriptor

Get

UINT8

07h (read/write/shared access)

5

Value

Get/Set

ENUM

If read, the actual value will be received. If written, the written value is reflected in attribute #6 until a reset. (Multilingual, see page Multilingual Strings)

Value

String

Meaning

00h

Disable

DHCP disabled (default)

01h

Enable

DHCP enabled

6

Configured Value

Get

ENUM

Holds the configured value, which will be written to attribute #5 after the module has been reset.

Value

String

Meaning

00h

Disable

DHCP disabled

01h

Enable

DHCP enabled

Important

Do not set this unless the end user explicitly would like to turn DHCP on. Normally the PROFINET IO Controller assigns the IP address.