Anybus® CompactCom 40 - PROFINET IRT IIoT Secure

Instance Attributes (Instance #21, F-Address)

This instance holds the F-Address, which is the PROFIsafe address for the safety module. This instance has no effect unless the attribute #1 (Safety enabled) is set to TRUE in the Functional Safety host object (instance #1). If the attribute is set to FALSE in the Functional Safety host object the application is advised to hide this instance to the end-user. See Functional Safety Object (E8h)

If this value is changed by the host application during runtime, a reset is required in order for changes to have effect.

#

Name

Access

Data Type

Description

1

Name

Get

Array of CHAR

F-Address

(Multilingual, see page Multilingual Strings)

2

Data type

Get

UINT8

05h (= UINT16)

3

Number of elements

Get

UINT8

01h (one elements)

4

Descriptor

Get

UINT8

03h (read/write access)

5

Value

Get/Set

UINT16

F-Address set by the host application.

Range: 1 - 65534 (Default: 1)

6

Configured value

Get/Set

UINT16

The configured value that will be used after restart