Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Connection Configuration

The connection configuration is set according to the table below:

Configuration Parameter

Value

Description/Comment

TCP send buffer size

8196 bytes

Minimum requirement from OPC UA

TCP receive buffer size

8196 bytes

Minimum requirement from OPC UA

Max message size

25576 bytes

-

Number of TCP connections

4

One TCP connection per secure channel plus one to provide a better error message to clients when out of sessions

Number of secure channels

3

One secure channel supported per session plus one more to provide a better error message to clients when out of sessions

TCP connection lifetime

2 min

If not attached to a secure channel the TCP connection can be overtaken after 2 minutes of inactivity

Security token lifetime

5 min

Minimum lifetime required

Number of sessions

2

Minimum requirement of the Micro Embedded Device Server profile

Max session timeout

5 min

-