Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Module

info.json
GET api/module/status/info.json

Response data:

Name

Data Type

Description

modulename

String

-

serial

String

32 bit hex ASCII

fwver

Array of Number

(major, minor, build)

uptime

Array of Number

The uptime is implemented as an array of two 32 bit values: [high, low] milliseconds (ms)

cpuload

Number

CPU load in %

fwvertext

String

Firmware version in text

vendorname

String

Vendor name (Application Object (FFh), instance attribute #8)

hwvertext

String

Hardware version in text

networktype

Number

Network type (Network Object (03h), instance attribute #1)

JSON response example:

{
   "modulename":  "ABCC M40",
   "serial":      "ABCDEF00",
   "fwver":       [ 1, 5, 0 ],
   "uptime":      [ 5, 123456 ],
   "cpuload":     55,
   "fwvertext":   "1.05.02",
   "vendorname":  "HMS Industrial Networks",
   "hwvertext":   "2",
   "networktype": 133,
}