Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Command Details: Get_Configuration_Data

Category

Extended

Details

Command Code:

13h

Valid for:

Object

Description

If the configuration data is requested from the network, the Anybus will issue this command to the application. The application shall send the stored configuration data in the response message.

Segmentation is used since the telegram length on the host interface is limited. The maximum total amount of configuration data that will be accepted by the module is 458 bytes.

This command must be implemented in order to support Configuration Data. If not implemented, the request will be rejected by the Anybus module.

  • Command Details

    Field

    Contents

    Comments

    CmdExt[0]

    00h

    -

    CmdExt[1]

    00h

    -

    MsgData[0... n]

    -

    No extended message data

  • Response Details (Success)

    Field

    Contents

    Comments

    CmdExt[0]

    00h

    (reserved, set to zero)

    CmdExt[1]

    Segmentation Control bits

    See Message Segmentation

    MsgData[0 - n]

    Status

    Configuration data from the application

  • Response Details (Error)

    Field

    Contents

    Comments

    CmdExt[0]

    00h

    (reserved, set to zero)

    CmdExt[1]

    Segmentation Control bits

    See Message Segmentation

    MsgData[0]

    Status

    Anybus protocol error code