This attribute holds a bit field which indicates the overall network status as follows:

Bit

Contents

Description

Comment

0

Link

Current global link status

1= Link sensed

0= No link

EtherCAT only: This link status indicates whether the Anybus CompactCom is able to communicate using Ethernet over EtherCAT (EoE) or not. That is, it indicates the status of the logical EoE port link and is not related to the link status on the physical EtherCAT ports.

1

IP established

1 = IP address established

0 = IP address not established

2

(reserved)

(mask off and ignore)

3

Link port 1

Current link status for port 1

1 = Link sensed

0 = No link

EtherCAT only: This link status indicates whether the Anybus CompactCom is able to communicate using Ethernet over EtherCAT (EoE) or not. That is, it indicates the status of the logical EoE port link and is not related to the link status on the physical EtherCAT ports.

4

Link port 2

Current link status for port 2

1 = Link sensed

0 = No link

Not used for EtherCAT

5... 15

(reserved)

(mask off and ignore)