Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Instance Attributes (Instance #1)

Extended

#

Name

Access

Type

Description

1

Energy Reading

Get

Struct of:

UINT32

UINT32

Amount of energy (Wh) consumed or produced by the application. Stored in nonvolatile memory.

The first UINT32 represents the lower part of the Energy Reading, the second UINT32 represents the higher part of the Energy Reading

2

Direction

Get

BOOL

Indicates if the host is consuming or producing energy.

Value:

Meaning:

0:

Producing

1:

Consuming

3

Accuracy

Get

UINT16

Accuracy in 0.01% of reading

0: Unknown

4

Current Power Consumption

Get

UINT16

The current power consumption in 0.01% of the Nominal Power consumption

5

Nominal Current Consumption

Get

UINT32

The nominal power consumption in mW