Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Instance Attributes

#

Name

Access

Type

Value/Description

1

Power Management Command

Get

DWORD

Collection of bit fields comprising the most recent power management request.

2

Power Management Status

Get

DWORD

Collection of bit fields providing Power Management status information.

3

Client Path

Get

Struct of:

Specifies the EPATH from this instance (server) to its current owner (client).

UINT (Path Size)

Size of path (in words)

Padded EPATH (Path)

4

Number of Power Management Modes

Get

UINT

Number of Power Management Mode array entries in attribute 5.

5

Power Management Nodes

Get

Array of:

Array of low power modes

Struct of:

Modes (Array of mode structures)

USINT

Minimum Pause Units (Specifies the unit of Minimum Pause Time)

UINT

Minimum Pause Time

USINT

Resume Units (Specifies the unit of Resume Time)

UINT

Resume Time (Required time to transition from the paused stated to the owned state.)

REAL

Power Level (Power in kW for this mode)

BOOL

Availability (Specifies whether this mode can be entered given the current device state)

6

Sleeping State Support

Get

BOOL

0 (Sleeping state not supported)