Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Instance Attributes (Instances #2... #8)

#

Name

Access

Type

Value/Description

1

Port Type

Get

UINT

Enumerates the type of port

2

Port Number

Get

UINT

CIP port number associated with this port

3

Link Object

Get

Struct of:

UINT

Padded EPATH

-

Path length (number of 16-bit words)

Logical path segments which identify the object for this port. The path must consist of one logical class segment and one logical instance segment. The maximum size is 12 bytes.

4

Port Name

Get

SHORT_STRING

Name of port, e.g. Port A. Max. 64 characters.

5

Port Type Name

Get

SHORT_STRING

6

Port Description

Get

SHORT_STRING

7

Node Address

Get

Padded EPATH

Node number of this device on port. The range within this data type is restricted to a Port Segment.

8

Port Node Range

Get

Struct of:

UINT (Min.)

UINT (Max.)

-

Min. node number on port

Max. node number on port

10

Port Routing Capabilities

Get

UDINT

1h (Routing of incoming Unconnected Messaging supported)

See also...

CIP Port Configuration Object (0Dh) , Instance Attributes..