Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Instance Attributes

#

Name

Access

Type

Value/Description

1

Parameter Value

Get/Set

Specified in attributes 4, 5 & 6.

Actual value of parameter

This attribute is read-only if bit 4 of Attribute #4 is true

2

Link Path Size

Get

USINT

0007h (Size of link path in bytes)

3

Link Path

Get

Packed EPATH

20 A2 25 nn nn 30 05h (Path to the object from where this parameter’s value is retrieved, in this case the ADI Object)

4

Descriptor

Get

WORD

Bit:

Contents:

0

Supports Settable Path (N/A)

1

Supports Enumerated Strings

2

Supports Scaling (N/A)

3

Supports Scaling Links (N/A)

4

Read only Parameter

5

Monitor Parameter (N/A)

6

Supports Extended Precision Scaling (N/A)

5

Data Type

Get

USINT

Data type code

6

Data Size

Get

USINT

Number of bytes in parameter value

7

Parameter Name String

Get

SHORT_STRING

Name of the parameter, truncated to 16 chars

8

Units String

Get

SHORT_STRING

(default string)

9

Help String

Get

SHORT_STRING

10

Minimum Value

Get

(Data type)

Minimum value of parameter

The Data Type is defined in attribute 5.

11

Maximum Value

Get

(Data type)

Maximum value of parameter

The Data Type is defined in attribute 5.

12

Default Value

Get

(Data type)

Default value of parameter

The Data Type is defined in attribute 5.

13

Scaling Multiplier

Get

UINT

0001h

14

Scaling Divisor

Get

UINT

15

Scaling Base

Get

UINT

16

Scaling Offset

Get

INT

0000h

17

Multiplier Link

Get

UINT

18

Divisor Link

Get

UINT

19

Base Link

Get

UINT

20

Offset Link

Get

UINT

21

Decimal Precision

Get

USINT

00h