Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Instance Attributes

Each instance corresponds to an instance within the Application Data Object (for more information, please consult the general Anybus CompactCom 40 Software Design Guide).

#

Name

Access

Type

Value/Description

1

Name

Get

SHORT_STRING

Parameter name (Including length)

2

ABCC Data type

Get

Array of USINT

Data type of instance value

3

No. of Elements

Get

USINT

Number of elements of the specified data type

4

Descriptor

Get

Array of USINT

Bit field describing the access rights for this instance

Bit:

Meaning:

0

1 = Get Access

1

1 = Set Access

2

(reserved, set to 0)

3

1 = Write process data mapping possible

4

1 = Read process data mapping possible

5

1 = NVS parameter

6

1 = Data notification enabled

5

Value

Get/Set

Determined by attributes #2, #3 and #9

Instance value

6

Max Value

Get

The maximum permitted parameter value.

7

Min Value

Get

The minimum permitted parameter value.

8

Default Value

Get

The default parameter value.

9

Number of subelements

Get

Array of UINT

Number of subelements in the ADI. Default value is 1 unless implemented in the application.

The size of the array depends on attribute #3.

Attributes #5–8 are converted to/from CIP standard by the module