Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Instance Attributes (Instance #20, QuickConnect)

This instance enables or disables the QuickConnect functionality from the application. Changes are valid after reset or power cycle. The value of the QuickConnect attribute (#12) in the TCP/IP Interface object (F5h), will change immediately.

This instance has no effect unless QuickConnect is enabled in the EtherNet/IP host object. If QuickConnect is disabled in the EtherNet/IP host object the application is advised to hide this instance to the end-user.

See also...

#

Name

Access

Data Type

Description

1

Name

Get

Array of CHAR

QuickConnect

2

Data type

Get

UINT8

08h (= ENUM)

3

Number of elements

Get

UINT8

01h (one element)

4

Descriptor

Get

UINT8

bit 0: 1 = Read access

bit 1: 1 = Write access

bit 2: 1 = Shared access

5

Value

Get/Set

ENUM

If read, the actual value will be received. If written, the written value is reflected in attribute #6 until a reset.

Value:

Meaning:

00h

Disable (default)

01h

Enable

6

Configured Value

Get

ENUM

Holds the configured value, which will be written to attribute #5 after the module has been reset.

Value:

Meaning:

00h

Disable

01h