Object Attributes (Instance #0)
# | Name | Access | Data Type | Value |
---|---|---|---|---|
1... 4 | - | - | - | Consult the general Anybus CompactCom 40 Software Design Guide for further information. |
11 | Max no. of instances | Get | UINT16 | 5+1 (Of the maximum number of instances there should always be one instance reserved for an event of severity level ‘Major, unrecoverable’, to force the module into the ‘EXCEPTION’-state.) |
12 | Supported functionality | Get | BITS32 | Bit 0: “0” (Latching events are not supported) Bit 1 - 31: reserved (shall be “0” ) |