Anybus® CompactCom 40 - EtherNet/IP IIoT Secure

Object Attributes (Instance #0)

#

Name

Access

Data Type

Value

1... 4

-

-

-

Consult the general Anybus CompactCom 40 Software Design Guide for further information.

11

Max no. of instances

Get

UINT16

5+1 (Of the maximum number of instances there should always be one instance reserved for an event of severity level ‘Major, unrecoverable’, to force the module into the ‘EXCEPTION’-state.)

12

Supported functionality

Get

BITS32

Bit 0: 0 (Latching events are not supported)

Bit 1 - 31: reserved (shall be 0 )